Previous product
Next product
![]() |
| ||||||||
UsageGriptop LD is flow applied by trowel to horizontal surfaces and has very good durability towards pedestrian and vehicular traffic. It also has very good resistance to many of the chemicals commonly found in an industrial environment (consult our Technical Department for further details). Griptop LD can be supplied in a variety of colours (consult our Sales Department for further details). Kit Form16Kg Specified Thickness Range2-4mm. CoverageApproximately 2.6m² per kit at 3mm thick. StorageStore at temperatures between 5°C and 30°C. Shelf LifeApproximately 12 months if stored in unopened containers and under good conditions. |
Technical Information
Griptop LD is non-tainting and has been tested to TES-S-002 by Campden BRI Group (test data available on request). Application InstructionSURFACE PREPARATION The surface must be clean, dry (less than 75% RH measured by hygrometer) and free of laitance (see the DCP Guide to Surface Preparation for further details). To ensure a good bond to the substrate, a 2mm deep x 3mm wide rebate should be cut around the edges of the floor, 150mm from the walls and running parallelto them. For treatment of surfaces containing expansion joints, consult our Technical Department. PRIMING Surfaces must be primed with Strongcoat Primer prior to application of Griptop LD (see Strongcoat Primer data sheet for further details). • More than one coat of primer may be required for highly porous or textured surfaces. For surfaces with RH between 75 and 85%, prime with 1 coat of Strongcoat DPM and allow to dry. For surfaces with RH greater than 86%, prime with 2 coats of Strongcoat DPM and allow the second coat to dry before priming with Strongcoat Primer. MIXING Taking care to ensure that the bottom and sides are thoroughly scraped, transfer the entire contents of the Griptop LD Hardener container into the Resin container and, using a Jiffy-type mixer attached to a slow running electric drill, mix for approximately two minutes. Once the Griptop LD Hardener and Resin have been mixed, transfer all the mixed material into a Casco or Creteangletype mixer, taking care to ensure that the bottom and sides are thoroughly scraped. Start the mixer and transfer to it the entire contents of the Griptop LD Filler container, taking care to ensure that these are completely dry and lump-free. Continue mixing for approximately two minutes. • Never mix Griptop LD by hand as this could lead to areas of uncured material. APPLICATION Once mixing is complete, transfer the Griptop LD to the primed surface and, using a straight-edged steel trowel, apply it evenly. Note: Griptop LD is not colour stable and may discolour on ageing and exposure to UV light, especially with light colours. This will not adversely affect the performance of the product. WORKING TIME Griptop LD has a working time of approximately 15 minutes at 20°C. • Never leave the mixed Griptop LD kit to stand for any length of time prior to application as this will considerably shorten its working time. FINISHING Whilst still wet, thoroughly spike roll the Griptop LD. CLEANING Once mixing, application and finishing are complete, tools can be cleaned with an appropriate cleaner. CURING TIME At 20°C, Griptop LD can be opened to heavy wheeled traffic after 24 hours. At the same temperature, it should be allowed to cure for five days before exposing to chemical contamination (consult our Technical Department for details of curing times at other temperatures). WORKING CONDITIONS Griptop LD should not be applied at temperatures less than 10°C. SLIP RESISTANT FINISHES For advice on slip resistant surfaces please consult our technical department. HEALTH & SAFETY Consult Material Safety Data Sheet prior to use. GENERAL GUIDANCE This information is for general guidance purposes only and may contain information that is inappropriate for certain conditions of use. Accordingly, all recommendations and suggestions are made without guarantee. Further information is available from our Technical Department. Please consult our Technical Department to confirm that this information is the current issue. |